Product >> Rolling Stock Cable
FIREROL FRL-TW-05MP-ESW-IOS
A.Conductor B.Insulation C.Screen D.Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Tinned annealed copper wires as defined in EN 50306-2
Insulation
LSZH special compound
Overall screen
Tinned annealed copper wires
Pair screen
Individual screened and sheathed. Screened according to EN 50306-3; Sheathed according to EN 50306-3 (S1. S2)
Pair Identification
Pairs numbered according to EN 50306-4
Outer sheath
LSZH special compound (S2. EM 101 - EM 104)
Electrical & Mechanical Properties
Nominal Voltage |
300/500 V |
Maximum Conductor Temperature |
+90/+105 deg (fixed installation) |
Minimum Permissible Ambient Temperature |
-25/-40 deg (fixed installation) |
Bending Radius |
10 x Overall Diameter |
Chemical & Environmental Properties
EN 60684-2 |
No fluorine |
EN 50305; EN 60811-2-1 |
Resistance to oil & fuel |
EN 50305 |
Resistance to ozone |
Fire Performance for rolling stock application
EN 50306-2 |
Hazard levels HL1, HL2/HL3, HL4 |
DIN 5510-2 |
Protection level 1/2/3/4 |
BS 6853 |
Interior use 1a, 1b, II; Exterior use 1a, 1b, II |
NF F 16-101 |
FO |
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 |
Vertical flame propogation for a single insulated wire or cable |
EN 50266-2-4 + EN 50305; IEC 60332-3C; |
Fire propagation of bunched wires and cables; |
VDE 0472 Teil 804; BS 4066-3; NFC 32070 |
|
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 |
Smoke density |
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 |
Halogen Free |
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 |
Corrosivity of gases (Acidity & Conductivity) |
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 |
Toxicity index |
NFF 16101; NFF 63808; BS6853 |
Smoke index |
FRL-TW-05MP-ESW-IOS 300/500 V
NUMBER OF CORES AND NOMINAL CROSS SECTION |
MINIMUM THICKNESS OF SHEATH AT ANY POINT |
OVERALL DIAMETER |
WEIGHT |
(mm²) |
(mm) |
min. (mm) |
max. (mm) |
(kg/km) |
2 x 2 x 0.5 |
1.0 |
10.1 |
11.3 |
100 |
3 x 2 x 0.5 |
1.0 |
10.8 |
12.0 |
150 |
4 x 2 x 0.5 |
1.0 |
11.8 |
13.0 |
180 |
7 x 2 x 0.5 |
1.0 |
13.9 |
15.5 |
270 |
|
|
|
|
|
2 x 2 x 0.75 |
1.0 |
10.9 |
12.1 |
120 |
3 x 2 x 0.75 |
1.0 |
11.6 |
12.8 |
170 |
4 x 2 x 0.75 |
1.0 |
12.8 |
14.0 |
220 |
7 x 2 x 0.75 |
1.0 |
15.1 |
16.7 |
330 |
|
|
|
|
|
2 x 2 x 1.0 |
1.0 |
11.3 |
12.5 |
130 |
3 x 2 x 1.0 |
1.0 |
12.0 |
13.2 |
190 |
4 x 2 x 1.0 |
1.0 |
13.2 |
14.4 |
235 |
7 x 2 x 1.0 |
1.0 |
15.7 |
17.3 |
370 |
|
|
|
|
|
2 x 2 x 1.5 |
1.0 |
13.3 |
14.5 |
180 |
3 x 2 x 1.5 |
1.0 |
14.0 |
15.6 |
260 |
4 x 2 x 1.5 |
1.0 |
15.5 |
17.1 |
340 |
7 x 2 x 1.5 |
1.0 |
18.7 |
20.3 |
540 |
|